Research Article

Thermomechanical Optimization and Comparison of a Low Thermal Inertia Mold with Rectangular Heating Channels and a Conventional Mold

Table 3

Variables and optimization criteria for both models.

MinMax

Circular modelAChannel diameter4 mm15 mm
BSteel thickness2 mm15 mm
CDistance between channels5 mm40 mm

Rectangular modelDSteel thickness2 mm15 mm
EHalf channel width5 mm20 mm
FChannel height2 mm10 mm
GDistance between channels5 mm40 mm
tObjective functionMinimize
ΔTConstraint function<2°C
uConstraint function<10 μm