Research Article

Mechanical Recovery of Cracked Fiber-Reinforced Mortar Incorporating Crystalline Admixture, Expansive Agent, and Geomaterial

Table 3

Mechanical recovery indices for three mixes at 56 days of healing.

TypeW (µm)FCPL (kN)Ploading (kN)Punloading (kN)Preloading (kN)Kloading (MPa)Kunloading (MPa)Kreloading (MPa)ISRIDR

OPC-56D720.394.001.541.88998.2290.140.23
730.364.151.591.93988.5310.130.25
1100.243.281.851.988810.0220.090.15
1120.263.301.862.017515.0220.100.12
1400.233.461.371.571508.9250.100.11

SH1-56D820.463.231.101.511178.7420.190.31
910.483.411.361.8113613.0540.220.33
1070.333.131.211.561046.9290.180.23
1100.353.111.721.84849.5250.090.21
1420.213.461.281.53986.8230.110.18
1470.182.731.201.36916.2180.100.14

SH2-56D780.713.451.742.211139.0750.270.63
850.693.501.712.1510014680.250.63
1110.502.721.181.48917.2350.190.33
1140.573.031.381.68868.8430.180.44
1430.303.651.291.691045.0270.170.22
1450.263.201.221.541106.8290.160.22