Research Article

Titanium Alloy Repair with Wire-Feed Electron Beam Additive Manufacturing Technology

Figure 5

Thermal profiles measured at (a) midthickness (thermocouple 1) and (b) midwidth (thermocouple 2) locations shown in Figure 1(a) during EBAM of a Ti6Al4V wall build (50 mm BH) on a 3 mm thick substrate.
(a)