Research Article
The Effects of Fiber Length and Volume on Material Properties and Crack Resistance of Basalt Fiber Reinforced Concrete (BFRC)
Table 8
Crack width of test specimens with different fiber volume fractions.
| Specimens | Fiber volume (%) | Crack width at each knife-edge (mm) | 1 | 2 | 3 | 4 | 5 | 6 | 7 |
| PC30 | 0 | 0.04 | 0.18 | 0.22 | 0.64 | 0.31 | 0.12 | 0.1 | BF 30-18-0.05 | 0.05 | 0.05 | — | 0.28 | 0.13 | — | 0.1 | 0.04 | BF 30-18-0.10 | 0.10 | 0.08 | — | 0.1 | 0.22 | — | — | 0.08 | BF 30-18-0.15 | 0.15 | 0.06 | — | | — | 0.06 | — | — | BF 30-18-0.20 | 0.20 | — | — | | — | — | — | — |
|
|