Research Article
Sealing Performance of Bionic Striped Mud Pump Piston
Table 2
Experimental scheme and results.
| Factor test | Stripe depth h (mm) | Angle α (°) | Pressure differences ΔP2 (MPa) | Increased rate of sealing β (%) |
| 1 | 1 | 45 | 0.044 | 42.11 | 2 | 1 | 60 | 0.027 | 64.47 | 3 | 1 | 90 | 0.014 | 81.58 | 4 | 2 | 45 | 0.021 | 72.37 | 5 | 2 | 60 | 0.022 | 71.05 | 6 | 2 | 90 | 0.007 | 90.79 | 7 | 3 | 45 | 0.060 | 21.05 | 8 | 3 | 60 | 0.034 | 55.26 | 9 | 3 | 90 | 0.030 | 60.53 | | 62.72 | 45.18 | | | | 78.07 | 63.59 | | | | 45.61 | 77.63 | | | | 32.46 | 32.46 | | |
|
|