Research Article

Application of Artificial Ground Freezing Technology in Modern Urban Underground Engineering

Table 2

Parameters similarity ratio in the model test.

ParameterSymbolDeductionValue

GeometryCl1 : 10
TemperatureCT1 : 1
TimeCt1 : 100
Seepage velocity10 : 1