Research Article

Interactive Buckling of Q420 Welded Circular Tubes under Axial Compression

Table 5

Existed local buckling limit for circular tubes.

Limit criterionD/t

Design codeGB50017-2017 [2]DL/T5154-2012 [19]ASCE48-05 [18]Eurocode 3 [16]AS4100 [20]AISC 360-10 [17]
Limit value100 (235/fy)26775/fy26220/fy90(235/fy)820.11 E/fy
Equal to “GB50017-2017”100(235/fy)113(235/fy)111(235/fy)90(235/fy)87(235/fy)97(235/fy)
Q42055.9563.2262.1150.3648.6854.27