Research Article
Interactive Buckling of Q420 Welded Circular Tubes under Axial Compression
Table 5
Existed local buckling limit for circular tubes.
| Limit criterion | D/t | | |
| Design code | GB50017-2017 [2] | DL/T5154-2012 [19] | ASCE48-05 [18] | Eurocode 3 [16] | AS4100 [20] | AISC 360-10 [17] | Limit value | 100 (235/fy) | 26775/fy | 26220/fy | 90(235/fy) | 82 | 0.11 E/fy | Equal to “GB50017-2017” | 100(235/fy) | 113(235/fy) | 111(235/fy) | 90(235/fy) | 87(235/fy) | 97(235/fy) | Q420 | 55.95 | 63.22 | 62.11 | 50.36 | 48.68 | 54.27 |
|
|