Advances in Materials Science and Engineering / 2020 / Article / Tab 4 / Research Article
Measurement and Prediction of Thermal Conductivity of Volcanic Basalt Rocks from Warsak Area Table 4 Fractional porosity, experimental thermal conductivity, and effective thermal conductivity obtained after using upper and lower thermal conductivity bounds.
Sample number Fractional porosity (Wm−1 ·K−1 )Wiener’s bounds H-S bounds WGM model Maxwell model Equation (1 ) Equation (2 ) Equation (3 ) Equation (4 ) Equation (5 ) Equation (6 ) BS-01 0.00267 3.024 3.491 2.580 3.486 3.123 3.455 3.486 BS-02 0.00341 3.014 3.488 2.405 3.482 3.032 3.442 3.482 BS-03 0.00586 3.060 3.480 1.963 3.470 2.765 3.401 3.470 BS-04 0.00633 2.481 3.478 1.897 3.467 2.719 3.393 3.467 BS-05 0.00787 2.626 3.473 1.706 3.459 2.578 3.368 3.459 BS-06 0.00827 2.985 3.471 1.663 3.457 2.544 3.361 3.457 BS-07 0.01137 2.196 3.461 1.389 3.441 2.306 3.310 3.441 BS-08 0.01242 2.074 3.457 1.316 3.436 2.235 3.293 3.436 BS-09 0.01373 2.772 3.442 1.235 3.429 2.152 3.272 3.429 BS-10 0.01878 2.465 3.435 0.997 3.403 1.882 3.192 3.403 BS-11 0.01917 2.374 3.433 0.983 3.401 1.864 3.186 3.401 BS-12 0.04569 2.195 3.337 0.481 3.262 1.097 2.798 3.268 BS-13 0.05221 2.542 3.319 0.439 3.236 1.016 2.710 3.236 BS-14 0.08724 2.254 3.197 0.277 3.066 0.675 2.282 3.066 BS-15 0.09432 2.003 3.172 0.257 3.032 0.631 2.204 3.032