Research Article
Out-of-Plane Shaking Table Tests on Seismic Response of RC Frame Infilled with a New Type of Shale Fired Heat-Insulation Blocks
Table 7
Analysis of result of displacement at the top of the wall.
| Specimen | Test factors | Displacement at top of the wall (mm) | A | B | C | 0.05 g | 0.1 g | 0.15 g | 0.2 g | 0.3 g | 0.4 g | 0.5 g | 0.6 g | 0.7 g | 0.8 g | |
| W-1 | 2 | 1 | 1 | 0.33 | 0.92 | 1.03 | 1.36 | 2.09 | 4.15 | 5.17 | 6.41 | 7.91 | 9.02 | 38.40 | W-2 | 1 | 1 | 2 | 0.41 | 1.01 | 1.08 | 1.57 | 2.21 | 4.41 | 5.56 | 7.65 | 7.97 | 10.55 | 42.42 | W-3 | 2 | 2 | 2 | 0.25 | 0.57 | 0.86 | 1.30 | 1.64 | 2.81 | 4.49 | 5.80 | 8.16 | 10.69 | 36.57 | W-4 | 1 | 2 | 1 | 0.23 | 0.47 | 0.84 | 0.94 | 1.32 | 2.73 | 3.81 | 4.86 | 7.15 | 8.20 | 30.56 | I | 80.82 | 74.97 | 78.99 | | | | | | | | | | | | II | 67.13 | 72.98 | 68.96 | | | | | | | | | | | | | 40.41 | 37.49 | 39.50 | | | | | | | | | | | | | 33.57 | 36.49 | 34.48 | | | | | | | | | | | | | 6.84 | 1.00 | 5.02 | | | | | | | | | | | |
|
|