Research Article

Investigation of Rotating Stall Phenomenon and Optimization in Mixed-Flow Waterjet Propulsion Device

Table 3

Results of each orthogonal experiment scheme.

SchemesSerial numbersOrthogonal experiment results
ABCDKQKHTη (%)FP-T (N·kW−1)

111110.07910.074372.6945.39
212220.08020.074373.4549.12
313330.08010.074073.1848.79
414440.08110.074173.9352.19
521230.07970.074273.0947.62
622140.08110.073974.0852.41
723410.07980.074372.8947.59
824320.08110.074274.1052.21
931340.08050.074073.5650.25
1032430.08130.073973.7852.74
1133120.08140.074174.2553.12
1234210.08060.074473.7550.46
1341420.08000.074072.9748.35
1442310.08000.074473.1548.36
1543240.08550.073577.2568.35
1644130.08540.073677.3368.12