Research Article

Influence of Structural Parameters of Shape Memory Alloy Corrugated Gaskets on the Contact Pressure of Bolted Flange Joints

Table 5

Range analysis.

FactorAverage contact pressure (MPa)
T (thickness)H (height)P (span)

1111540.77
2122542.55
3133601.4
4213702.77
5221705.44
6232963.18
7312902.16
83231112.52
93311245.36
K1561.57715.23872.15
K2790.46786.83830.22
K31086.68936.64736.33
Range175.0373.80445.27