Research Article

Collapse Behaviour of a Concrete-Filled Steel Tubular Column Steel Beam Frame under Impact Loading

Table 1

Detail information of the testing specimens.

Specimen labelBoundary conditionD(B) × ts × L (mm × mm × mm)V (m/s)M (kg)Preloading (kN)Reference

MSHPinned-pinned□100 × 2 × 25003.57592288[22]

Pd1Fixed-sliding○100 × 2 × 10007.00625.450[23]
Pd2Fixed-sliding○100 × 2 × 10006.99825.4588
Pd3Fixed-sliding○100 × 2 × 10006.99525.45163
Pd4Fixed-sliding○100 × 2 × 10007.01225.45196
Pd6Fixed-sliding○100 × 2 × 10007.00625.45228

HCCFixed-fixed○180 × 3.65 × 19407.734650[24]
CC1Fixed-fixed○180 × 3.65 × 19409.214650
CC2Fixed-fixed○180 × 3.65 × 19406.49200
CC3Fixed-fixed○180 × 3.65 × 19409.674650
HSSPinned-pinned○180 × 3.65 × 28004.254650
SS1Pinned-pinned○180 × 3.65 × 28008.054650
SS2Pinned-pinned○180 × 3.65 × 28005.699200
SS3Pinned-pinned○180 × 3.65 × 28008.934650

The specimens with asterisk in label are hollow steel tubes.