Research Article
Characterization of TiZrN and TaZrN Nanocomposite Multilayer Coating Deposited via RF/DC Magnetron Sputtering on AISI4140 Steel
Table 4
Details of testing parameters in constant humidity condensation atmosphere test (ref. 6270:2005 (E)).
| Humidity | 98% when measured with a hygrometer during a test | Temperature | 35 to 45 degrees Celsius | Pr. of air for atomizing | Infinitely variable from 2 to 3 bar with pressure regulator | Mixed with brine (5% of sodium chloride, 1% of magnesium chloride, and deionized water 94% | For 1 liter of solution | pH of the solution | Maintained at 7.5 by the addition of a buffer solution | pH improvement | Measured every 8 hours | Some service providers | Tied with plastic wire and hanged on the hanger |
|
|