Research Article

Statistical Modeling and Optimization of Laser Cladding Stellite 6/WC Composite Coating

Table 8

Optimization objectives and scheme.

NameCriteriaLowerUpperImportance

LP (W)Maximize5007005
V (mm/min)In range2004003
CSD (mm)Minimize0.70.95
WCC (%)In range0303
Porosity area (μm2)In range35627.63997883
Flatness (mm)In range0.1610.6363
Hardness (HV 0.2)In range319.9675.93