Key concrete temperature data at core measurement location T3.

Specimen no.Peak hydration heat (°C)Average heating rate (°C/h)Temperature at 5 d (°C)Average cooling rate (°C/h)Maximum internal/external temperature difference (°C)Temperature at 7 d (°C)

130.30.823.80.272.7−1.3
266.31.8960.20.784.714.9
354.61.8239.40.6615.32.3
468.01.9260.30.807.315.4