Research Article
Research on Dynamic Compressive Performance of Polypropylene Fiber-Reinforced High-Strength Concrete under Freeze-Thaw Environment
Table 3
Dynamic compression test results.
| Label | Times of freeze-thaw cycles | Velocity (m/s) | Strain rate () | The peak intensity of stress-strain curve (MPa) |
| FT0 | 0 | 6.24 | 79 | 69.31 | FT25 | 25 | 6.26 | 78 | 67.76 | FT50 | 50 | 6.25 | 81 | 65.78 | FT75 | 75 | 6.26 | 77 | 66.44 | FT100 | 100 | 6.25 | 78 | 64.65 | AVG | — | 6.252 | 78.6 | — | FT0 | 0 | 7.9 | 107 | 77.56 | FT25 | 25 | 7.9 | 109 | 73.44 | FT50 | 50 | 7.9 | 98 | 73.62 | FT75 | 75 | 8 | 105 | 74.98 | FT100 | 100 | 7.9 | 104 | 73.12 | AVG | — | 7.92 | 104.6 | — | FT0 | 0 | 8.9 | 133 | 85.42 | FT25 | 25 | 8.9 | 131 | 85.39 | FT50 | 50 | 9 | 130 | 84.27 | FT75 | 75 | 8.9 | 139 | 84.05 | FT100 | 100 | 8.9 | 133 | 86.07 | AVG | — | 8.92 | 133.2 | — | FT0 | 0 | 11.4 | 205 | 99.81 | FT25 | 25 | 11.4 | 201 | 99.23 | FT50 | 50 | 11.4 | 204 | 102.11 | FT75 | 75 | 11.5 | 213 | 92.54 | FT100 | 100 | 11.4 | 218 | 98.39 | AVG | — | 11.46 | 207.8 | — |
|
|