Research Article

HIT Solar Cells with N-Type Low-Cost Metallurgical Si

Table 2

Comparison of HIT solar cell properties with metallurgical and Siemens Si samples.

Cell parametersSiemens SiMetallurgical Si Simulated dataOptimized data

(V)0.72940.69490.68410.7061
(mA/cm2)38.91837.56437.65639.641
FF (%)78.3777.4875.0881.08
(%)22.2520.2319.5821.17
TC (%/°C)−0.225−0.3043−0.2000−0.2000