Research Article

In Vitro Comparison of Dynesys, PEEK, and Titanium Constructs in the Lumbar Spine

Table 2

Reduction in ROM at L4-L5 compared to previous studies.

Reduction in ROM normalized to intact
Flex.Ext.LB AT

DSS-FEM51%40%30%29%
DSS54%39%45%70%
DSS55%46%41%
DYN57%48%−5%
DYN66%60%5%
PEEK61%53%20%
TI64%66%27%
RR74%62%71%26%
RR71%76%58%
RR-FEM76%66%62%48%

Indicating treatment from Schmidt et al. [26]; indicating treatment from Schilling et al. [13]; DSS-FEM = predicted dynamic stabilization from finite element model; DSS = Dynamic Stabilization System; DYN = Dynesys; TI = Titanium rod; RR = rigid rod; RR-FEM = predicted rigid stabilization from finite element model.