Research Article

Calculation of Thermal Pressure Coefficient of R11, R13, R14, R22, R23, R32, R41, and R113 Refrigerants by Data

Table 4

Comparison of among the calculated and experimental values for R11 at 400 K [1, 18, 30].

MPa mol L−1 (MPa K−1)
TPCHelmholtzTPC(1)TPC(2)TPC(3)

1.40748.63180.38340.79860.43120.4310
2.10008.68270.39480.81200.43750.4375
3.10008.75090.40650.83010.44600.4462
4.10008.81420.41740.84720.45390.4544
5.10008.87320.42760.86330.46140.4621
6.10008.92860.43730.87870.46850.4694
7.10008.98100.44650.89330.47530.4764
8.10009.03060.45540.90740.48180.4831
9.10009.07800.46380.92100.48800.4895
10.10009.12320.47190.93400.49400.4957
11.10009.16650.47970.94670.49980.5017
12.10009.20810.48720.95890.50530.5075
13.10009.24810.49450.97080.51070.5131
14.10009.28680.50150.98240.51600.5185
15.10009.32410.50830.99370.52110.5238
16.10009.36020.51491.00460.52600.5289
17.10009.39520.52141.01540.53090.5339
18.10009.42920.52771.02590.53560.5388
19.10009.46230.53381.03610.54020.5436
20.10009.49440.53981.04620.54470.5483
21.10009.52570.54561.05600.54910.5529
22.10009.55620.55131.06570.55340.5574
23.10009.58590.55691.07520.55760.5618
24.10009.61500.56241.08450.56170.5661
25.10009.64340.56781.09370.56580.5703