Research Article

Electrochemical Investigation of Catechol at Poly(niacinamide) Modified Carbon Paste Electrode: A Voltammetric Study

Table 1

Comparison of linear range and detection limits for catechol with different classical methods and electrodes.

Classical methodsElectrode/modifier biosensorsDetection limits (µM)Detection Potential (V)Refs.

DPVBare indium tin oxide electrode1.00.26[9]
DPVDL-norvaline modified GCE0.80.37[11]
DPV[Cu(Sal-β-Ala)(3,5-DMPz)2]/SWCNTs/GCE1.460.07[26]
DPVGCE/with a composite consisting of silver nanoparticles (AgNPs), polydopamine, and graphene0.1[27]
DPVPASA/MWNTs composite film modified GCE1.0[28]
CVPoly-NA modified CPE1.490.20Present work

DPV: differential pulse voltammetry; CV: cyclic voltammetry; GCE: glassy carbon electrode; Sal: salicylaldehyde; β-Ala: β-alanine; 3,5-DMPz: 3,5-dimethylpyrazole: SWCNTs: single-walled carbon nanotubes; PASA/MWNTs: polyamidosulfonic acid and multiwall carbon nanotubes.