Research Article

Analysis and Minimization of the Oscillatory Currents in Multibranch Thyristor-Switched Capacitors

Table 1

The optimal switching angles ( ).

Compensator
step rating
per unit per unit per unit

90 90 90
83 77 71.44
80 71.5 63.64
78 67.2 57.57