Abstract

The over-current condition for a traction inverter can indicate flaws on control algorithms, interference on logic signals, hardware aging, or hardware misconduct. Thus, proper detection of over-current conditions during inverter operation is a critical item for inverter development and product validation. This paper reviews several widely used over-current detection methods and a few theoretically approved over-current detection methods. The main focus of this review includes the sensing bandwidth, sensing accuracy, and implementation complexity of the studied over-current detection methods. The advantages of those widely used methods and the application requirements for the theoretically and prototypingly approved methods are concluded by this review.

1. Introduction

In industrial applications and automotive applications, traction inverters are commonly used to convert DC input to AC output. The operating condition of a traction inverter can affect the power conversion output characteristics, the DC input’s performance, and the inverter’s self-reliability. Current and temperature are two of the critical metrics for inverter operation reliability. Inverter components such as power semiconductor and DC link capacitors are designed to operate within a safe current range and temperature range. Out-of-range inverter operation can result in poor inverter efficiency, quick aging of the inverter components, and permanent damage on critical inverter components [1]. Generally, critical components’ temperature and current capability are cross-coupled. Thus, the inverter over-current detection sometimes can induce the consideration of inverter operating temperature [2].

State-of-the-art reviews on traction inverter current sensing have categorized existing methods based on sensing locations, monitoring signals, and complexity of hardware/software implementation [3, 4]. Separate discussions for traction inverter open-circuit faults and short-circuit faults clarify the application of traction inverter current sensing on the two major inverter operation faults [4]. The short-circuit fault can result in a sudden current increase in the traction inverter, and the study in [4] falls into the category of this review. The temperature sensing on inverter’s critical components, for instance, switching power semiconductor, can sometimes include current sensing. The temperature-current look-up tables in [5] indicate that, in some applications, accurate current sensing, especially at high current conditions, is a factor for accurate temperature sensing.

Under fault-free operations, over-current detections usually require high sensing accuracy since a small percentage of current change at high current or marginal over-current operation can induce large inverter loss change [6, 7]. Switching power semiconductors’ tolerable short-circuit time is usually several microseconds under a short-circuit fault condition. As a result, the sensing bandwidth or response time for inverter over-current detections is critical. Another critical metric to evaluate inverter over-current detection methods is implementation complexity. In applications like electric vehicles, compact and low-cost design for traction inverter is widely accepted. Thus, a detection method with simple implementation can be more competitive over those complex methods.

This review discusses several widely used over-current detection methods for traction inverters. Based on the discussion on sensing bandwidth, sensing accuracy, and implementation complexity, the advantages of those widely used over-current detection methods are provided. Potential commercialization requirements for those theoretical and prototypingly approved methods are concluded by this review.

2. Over-Current Locations in a Traction Inverter

The three-phase output over-current of a traction inverter occurs on the three-phase connections between the traction inverter and the three-phase load. It is common to sense an inverter’s three-phase output current at the location as marked in red in Figure 1. Current sensors are commonly set up at this location for phase current sensing. Under fault-free inverter operations, this can also be a location for inverter output over-current detection. Note that an inverter’s three-phase output current can also be sensed at other locations as the following discussed.

The red locations in Figure 2 show the locations for inverter high-low side short-circuit detection. The inverter high-low side short circuit is a faulty operating condition and can induce a very high current in a short period of time. To protect the switching power semiconductor from over-current failure, the response time of this over-current condition should be less than the maximum allowable short-circuit time of the switching power semiconductors.

Under a fault-free operating condition, the locations in Figure 2 can also be used for three-phase output over-current detection.

The red locations in Figure 3 shows the locations for inverter DC link short-circuit detection. Similar to the inverter high-low side short circuit, the DC link short-circuit is another faulty operation and can induce a very high current in a short period of time. Thus, a fast response time is required for over-current detection at this location. Note that the DC link short-circuit detections are not necessarily set up inside the inverter. Setting up the DC link short-circuit detection in the DC power source (a power battery, a DC power supply, etc.) is an alternative.

The earth ground or the housing of the traction inverter is usually configured so it has the same voltage as the DC link voltage’s midpoint or the low point. An inverter hotline-to-earth ground short, as shown in Figure 4, can also induce a very high current in a short period of time. The detection of this over-current condition is usually a combination over-current detection at locations as shown in Figures 13.

3. Over-Current Detection Methods

3.1. Magnetic Field-Based Over-Current Detection

The magnetic field-based current sensing utilizes the circulating magnetic field generated by the phase current in a busbar. As shown in Figure 5, a C-shape ferrite core (colored with light blue) is used to constrain the generated magnetic field, and a hall-effect field detector (colored with red) is used to measure the field density. With a proper design of the shape of the ferrite core, the field density in the airgap of the C-shape ferrite core can be to-scale of the busbar current [8]. Note that in some applications, the C-shape ferrite core can be replaced with a U-shape shield [9]. With proper field decoupling solutions, less than 1% sensing error can be achieved without using any magnetic field constrains (a U-core or a C-shield) [10].

The magnetic field-based current sensing methods are commonly used for traction inverter phase current sensing as shown in Figure 6. Generally, the sensing range of the phase current sensor will be set to 1.3 to 1.5 times the full load current so the redundancy can be used for over-current detection. As afore-discussed, as long as the magnetic field constrains are not saturated, the over-current detection can be as accurate as the in-range phase current sensing.

The over-current response time of a hall-effect field detector output can be several microseconds [11]. However, due to the switching noise on the inverter output phase, RC-type filters are commonly used on the outputs of the inverter phase current sensor [12]. Thus, the response time can be further reduced.

The magnetic field-based current sensors do not have a galvanic connection to the phase-current busbar. As a result, no signal isolation is required and the hall-effect field detector can share the same power supply with the inverter’s microcontroller. If any magnetic field constraints (such as a C-shape core or a U-shape shield) are used, the current sensor can be bulky.

3.2. Shunt Resistor-Based Over-Current Detection

The shunt resistor-based current sensing detects the voltage drop across a resistor and estimates the current through the resistor based on . In a traction inverter application, a common design for a shunt resistor is a small piece of alloy with a very low resistance-temperature dependency and the sensing accuracy can achieve less 1% error [13]. Because the measurement of the voltage drop across the shunt requires a galvanic connection to the busbar, an isolation circuitry can be required between the current sensor and the microcontroller, as shown in Figure 7. Similar to the magnetic field-based current sensing, if a shunt is used for traction inverter phase current sensing as shown in Figure 8, the sensing range can be set up-to 1.3 to 1.5 times the full load current so the redundancy can be used for over-current detection.

If an isolation circuitry is used, the shunt resistor-based over-current detection’s response time will mostly rely on the response time of the isolation circuitry. Some commercialized solutions can provide an up-to several nanoseconds response time [14].

If shunt resistors are set up at the location as shown in Figure 2, the over-current detection circuitry can share the same power supply with the gate drive. The benefit of having the over-current detection circuitry and the gate drive to share the same power supply is that the over-current feedback can directly regulate the gate drive without signal isolation. Regan at al. [15] has proposed various of shunt resistor-based over-current detection solutions. A typical solution is shown in Figure 9. Because of the usage of the filtering capacitor Cfilt, the response time can be several nanoseconds to several microseconds.

3.3. Detection on a Power Semiconductor

When a power MOSFET or an IGBT is on, the device’s on-state voltage drop will increase with the forward current. Thus, the on-state voltage drop of switching power semiconductor can be used for over-current detection. Considering that the power semiconductor’s “on-state voltage-to-forward current” relationship is temperature-sensitive, this method may not meet the accuracy for current regulation. Usually, this method is used for high-low side short-circuit detection as afore-discussed with Figure 2. When a high-low side short-circuit occurs, a very large on-state current will pull the device into saturation. By detecting on-state voltage drop and turn off the power semiconductor switch before the device saturates, a high-low side short-circuit faulty operation can be stopped. This type of over-current detection is also named as desaturation protection.

In [16], two typical over-current detection solutions are proposed based on desaturation circuit, as shown in Figures 10 and 11. In the case of Figure 10, a high over-current will generate a large on-state voltage across the power switch. The voltage across Cblk will track the on-state voltage and eventually trigger the over-current protection. The response time of the over-current detection mostly depends on the output rating of the constant current source Ic and Cblk. Due to the high switching noise across the power switch, Cblk is required and it results in tens of nanoseconds to several microseconds’ delay. Some switching power semiconductor has an internal current sensing output as shown in Figure 12. The afore-discussed desaturation circuit can also be used for over-current detection.

The benefit of using the desaturation circuit is that the sensing circuitry can share the same power supply with the gate drive. In [16], a gate drive solution that integrates the desaturation circuit into the gate drive IC is provided.

3.4. Detection with the Power Semiconductor Gate Drive Circuitry

The interaction between the gate drive and the switching power semiconductor during the switching transient can be correlated to the device current and device junction temperature [17]. If the effect of junction temperature is mild or can be decoupled, the gate drive switching performance can be used for switching power semiconductor over-current detection. Generally, over-current detection using gate drive switching performance is used at locations as shown in Figure 2. Niu and Lorenz [18] proposed a method to use gate drive output current for over-current detection as shown in Figure 13. In [1922], several over-current detection methods based on gate drive output voltage are proposed. The methods using gate drive switching performance generally require signal processing to correlate the measurement to the power device’s current.

Because of the temperature dependency and the power semiconductor part-to-part variation, most of the gate drive-based over-current detection cannot achieve very high accuracy. For those methods based on the gate drive switching transient, every current measurement is achieved right after the switching transient. If a short-circuit occurs at the middle of a conduction cycle, over-current can only be detected after the next switching transient.

4. Hardware and Software Implementations

The applications of the afore-discussed methods on different over-current detecting locations are summarized in Table 1. The magnetic field-based current sensing methods and the shunt resistor-based current sensing methods can be applied to all three over-current detecting locations. For the over-current detecting methods based on “detection on power semiconductor” and “detection with gate drive,” the most suitable applications will be the inverter high-low side short-circuit detection.

The power supply solutions for the afore-discussed over-current detection methods are summarized in Table 2. The magnetic field-based over-current detection circuitry is galvanic isolated to the conductor. Thus, it can share a power supply with the inverter controller and directly communicate with the controller. The shunt resistor-based over-current detection circuitry will directly connect to the high current conductor, and it is suitable to have an independent isolated power supply. For the over-current detecting methods based on “detection on power semiconductor” and “detection with gate drive,” since the detecting components (the power semiconductor or the gate drive) is directly driven by the gate drive power supply, it is suitable to have the detecting circuitry to share the same power supply with the gate drive.

For the “magnetic field-based methods,” “shunt resistor-based methods,” and the “methods based on detection on power semiconductor,” the measurement can be directly compared to a threshold to validate the over-current condition. The methods based on “detection with gate drive” can require complex signal processing such as peak detection, integration, high-resolution time count, and so forth. As a result, hardware/software implementation can be expensive. The aforementioned signal processing requirements are summarized in Table 3.

This paper has covered the discussion for over-current sensing response time. The response time for the aforementioned over-current sensing methods can be case-by-case due to the selection of filtering circuity and sampling frequency. Instead of directly providing a response time comparison, a comparison of dominant sensing response time contributors is listed as shown in Table 4. Generally, the “magnetic field-based methods” and the “methods based on detection on power semiconductor” have the dominant sensing response time contribution from RC filter-induced delay because of the switching transient induced noise. The “shunt resistor-based methods” are more dominated by the isolation delay. For the methods based on “detection with gate drive,” over-current detection only occurs at the switching transient. Thus, the largest possible sensing response time is the time period between two switching transient actions.

5. Conclusions

This paper reviews several widely used over-current detection methods and a few theoretically approved over-current detection methods. The application and the popularity of the discussed over-current detection methods rely on their sensing accuracy, sensing bandwidth, and implementation complexity. Suitable over-current detecting locations, circuitry power supply selections, and requirements for signal processing are concluded.

Conflicts of Interest

The authors declare that they have no conflicts of interest.