Abstract

Background and Objective. The lateral masses of axis have good cancellous bone quality beneath the articular surface of facets that make this area a good site for the insertion of an internal fixation device. Methods. 60 dry axis vertebrae were obtained for anatomic evaluation focused on pedicle, superior and inferior articular facets, and foramen transversarium. Based upon linear and angular parameters the mean, range, and standard deviation were calculated. Results. The mean length, width, and height of the pedicle were 21.61 ± 2.37 mm, 8.82 ± 2.43 mm, and 5.63 ± 2.06 mm. The mean pedicle superior angle and median angle were 23.3 and 32.2 degrees. The mean superior articular facet length, width, and external and internal height were 16.34 ± 1.56 mm, 14.35 ± 1.75 mm, 8.98 ± 1.36 mm, and 4.23 ± 0.81 mm. Depth of vertebral artery was 4.72 ± 0.83 mm. Mean inferior articular facet length and width were 11.13 ± 1.43 mm and 7.89 ± 1.30 mm. The mean foramen transversarium length and width were 5.11 ± 0.91 mm and 5.06 ± 1.23 mm. Conclusions. The study may provide information for the surgeons to determine the safe site of entry and trajectory for the screw implantation and also to avoid injuries to vital structures while operating around axis.

1. Introduction

Axis, the second cervical vertebra, forms a pivot on which the atlas rotates carrying the head to allow greater range of motion at the atlantoaxial joints [1, 2]. The lateral masses of axis have good cancellous bone quality beneath the articular surface of facets that makes this area a good site for insertion of an internal fixation device [3].

The elements of pedicle and pedicle axis are critical to the structural anatomy of axis vertebra which are important to normal function and also for cases of pathology or fractures when surgical intervention is required [4, 5]. The superior articular facets (SAF) of axis differ from other vertebral facets which make this region more prone to vertebral artery injury during screw fixation [6]. In axis vertebrae the SAF lies in proximity to the body and medial aspect of the axis of the pedicle whereas SAF of other vertebrae are lying in proximity to the junction of pedicle and lamina and also the vertebral artery foramen is lying partially or completely in the undersurface of axis while in other vertebrae the vertebral artery foramen is located entirely in relation to foramen transversarium [7, 8]. This unusual location of vertebral artery foramen makes the vertebral artery more prone to injury during screw fixation [9].

The present study may also assist with placement of screws into pedicle or lateral mass. For this reason, the posterior point of projection of the pedicle axis has been defined in terms of reference points visible in a postsurgical approach to the cervical spine and the two angles represent the safe bounds for transpedicular screw fixation/placement [4, 10]. Thus if there is any variation in the lateral mass of axis or associated anomalous vertebral artery, it may lead to thinning of lateral mass and pedicle would prevent adequate fixation of transpedicular screw and vertebral artery will also be at risk [2].

Therefore, the present study was designed to know the dimensions of lateral masses of axis that are important to analyze their relationship with the vertebral artery and also to determine the ideal drill angle for accurate placement of a screw in the area resulting from fracture or partial sublaxation [4]. Thus it would be essential for the clinicians and surgeons to have a proper orientation of the anatomy, dimensions, and special features of this unique vertebra.

2. Material and Methods

The study was conducted on 60 dry axis vertebrae obtained in the Department of Anatomy, Government Medical College, Amritsar. The measured parameters included dimensions regarding lateral masses of axis vertebrae focused on pedicle, superior articular facet, inferior articular facet, foramen transversarium and pedicle angles. Fifteen parameters were measured and all the measurements were made using a vernier caliper accurate to 0.1 mm. The angles were measured by using an iron wire, scale, and a protractor. Based upon linear and angular parameters the mean, range, and standard deviation were calculated. The statistical analysis of the measurements of right and left sides was also done (Table 1 and Figures 1, 2, 3, 4, and 5).

To measure the angles first point of pedicle axis projection would be defined which was determined by drawing two lines parallel to the axis, one on superior surface of the pedicle and the other on medial side of the pedicle. These two lines intersected on the posterior aspect of the lateral mass.

3. Results

The measurements of all parts of lateral mass of axis vertebrae including the angles showed uniformity and there was no significant statistical difference observed in the mean dimensions of the parameters measured. The pediclelength, width, and height were  mm,  mm, and  mm, respectively. Length and width of superior articular facet were  mm and  mm. External and internal height were  mm and  mm. Thus  mm is depth of vertebral artery calculated as the difference between external and internal height. Length and width of inferior articular facet were  mm and  mm. The foramen transversarium length, width, and depth were found to be  mm,  mm, and  mm, respectively. Pedicle superior angle was 23.3 degrees and pedicle median angle was 32.2 degrees (Table 2).

4. Discussion

Detailed knowledge of pedicle would be essential if transpedicular screw placement is desired to stabilize a fracture line through pedicle [4, 14, 15]. Pedicle angles represent the safe bounds for transpedicular screw fixation.

A glance at Table 3 elucidates that, in the present study, the parameters of pedicle length, pedicle width, and pedicle height of right and left sides were compared and no significant statistical difference was observed in the mean dimension of the parameters studied on the two sides of the vertebrae. None of the earlier authors have compared the parameters of both the sides in the available accessible literature and the difference of mean of pedicle length (PL) was (), width (PW) was (), and height (PH) was (), respectively, which was found to be statistically insignificant.

The values of superior articular facet external height (SAFHE) reported in the present study stood equivalent to Madawi et al. (1997) [2] and Gupta and Goel (2000) [9] and the values of right and left sides were also calculated and the difference between mean dimensions of external height of both the sides was observed to be statistically insignificant () whereas the superior articular facet internal height (SAFHI) in the present study stand equivalent to Madawi et al. (1997) [2] and Gupta and Goel (2000) [9] and the difference between the mean dimensions of internal height of right and left sides was also found to be statistically insignificant (). It is also interpreted in Table 3 that the findings of depth of vertebral artery in the present study stands equivalent to Madawi et al. (1997) [2] and Gupta and Goel (2000) [9] and are statistically not significant ().

A glance at Table 3 also showed that in the present study the difference of mean of foramen transversarium length (FTL) was (), width (FTW) was (), and depth was (FTD) (), respectively, which was found to be statistically insignificant and also these parameters showed no major difference when compared with the workers reported in the literature. The pedicle superior angle (PSA) in the present study was slightly less as compared with work done by Madawi et al. (1997) [2] and more to Xu et al. (1995) [4]. No significant statistical difference was observed in the mean dimension of the angles studied on the two sides of the vertebrae () whereas the pedicle median angle (PMA) was in accordance to the work done by Xu et al. (1995) [4] and Madawi et al. (1997) [2]. No significant statistical difference was observed in the mean dimension of the angles studied on the two sides of the vertebrae ().

A glance at Table 4, in the present study the length of superior articular facet (SAFL) in North Indian population showed very slight difference when compared with the study of Francis (1955) [13], Xu et al. (1995) [4], and Gupta and Goel (2000) [9]. The difference between the mean of length of right and left superior articular facet of axis was found to be statistically insignificant () and width of SAF (SAFW) in North Indian population showed very slight difference when compared with the study of Francis (1955) [13], Xu et al. (1995) [4] and Gupta and Goel (2000) [9]. The difference between mean of width of right and left superior articular facet of axis was found to be statistically insignificant ().

Values of inferior articular facet length of axis (IAFL) in the present study stood equivalent whereas inferior articular facet width (IAFW) was found to be less when compared with work done by Francis (1955) [13] and Gupta and Goel (2000) [9]. But the comparison of right and left sides was not specified by them. No significant statistical difference was observed in the mean dimension of the IAFL () and IAFW () studied on the two sides of the vertebrae.

5. Conclusions

The study may provide information for the surgeons to determine the safe site of entry and trajectory for the screw implantation and also toavoid injuries to vital structures while operating around axis. Dimensions of axis vertebral foramen transversarium are important and act as a useful guide in the estimation of dilation of vertebral artery. The vertebral artery and the basilar artery contribute blood supply not only to the brain but to inner ear also and their compression may lead to irritation of sympathetic plexus, manifested not only by neurological symptoms but also by labyrinthine or hearing disturbances. Thus dimensions of axis vertebral foramen transversarium are important and act as a useful guide in the estimation of dilation of vertebral artery [12, 16, 17]. SAF of axis has a crucial relationship with vertebral artery that makes the vertebral artery more prone to injury. Asymmetry of articular processes in particular hypertrophy of articular processes might have caused torticollis with severe constriction of cervical mobility [18]. To determine accurate placement of a screw in the area of any deformity resulting from fracture or partial sublaxation, ideal drill angle for transpedicular screw placement is required. Therefore careful anatomic reduction is essential [4, 19].

Conflict of Interests

The authors declare that there is no conflict of interests regarding the publication of this paper.