Review Article
Recommendations for Haemodynamic and Neurological Monitoring in Repair of Acute Type A Aortic Dissection
Table 1
Essential and desirable monitoring techniques for use in repair of acute type A aortic dissection.
| Essential monitoring |
| Electrocardiogram | Arterial oxygen saturations | Peripheral and core temperatures | Central venous pressure | Pre- and postarch arterial lines | Transoesophageal echocardiogram |
| Desirable monitoring |
| Pulmonary artery flotation catheter | Continuous intra-arterial blood gas monitor | Near infrared spectroscopy (cerebral and peripheral) | Jugular venous oxygen saturations | Transcranial Doppler | Electroencephalography |
|
|