Review Article

Recommendations for Haemodynamic and Neurological Monitoring in Repair of Acute Type A Aortic Dissection

Table 1

Essential and desirable monitoring techniques for use in repair of acute type A aortic dissection.

Essential monitoring

Electrocardiogram
Arterial oxygen saturations
Peripheral and core temperatures
Central venous pressure
Pre- and postarch arterial lines
Transoesophageal echocardiogram

Desirable monitoring

Pulmonary artery flotation catheter
Continuous intra-arterial blood gas monitor
Near infrared spectroscopy (cerebral and peripheral)
Jugular venous oxygen saturations
Transcranial Doppler
Electroencephalography