Electrochemical Determination of Diclofenac by Using ZIF-67/g-C3N4 Modified Electrode

Table 2

Comparison of the analytical performance of the different modified electrodes for the determination of DCF.

ElectrodesTechniqueLinear range (μM)LOD (μM)References

Gold nanoparticle/multiwalled carbon nanotube modified glassy carbon electrodeSWV0.03–2000.02[9]
Cu-doped zeolite-expanded graphite-epoxy electrodeDPV0.3–200.05[36]
APTES-amino-AT-silica/GCESWV0.3–200.053[37]
Gold nanoparticles decorated multiwalled carbon nanotubes/graphene oxide/AuEDPV0.4–800.09[38]
Ionic liquid modified carbon nanotube paste electrodeDPV0.5–3000.2[7]
Amino-AT/GCESWV0.3–200.204[37]
Au-Pt bimetallic nanoparticles decorated multiwalled carbon nanotubes/gold electrodeDPV0.5–10000.3[39]
ZIF-67/g-C3N4DPV0.2–2.20.071The present work

Square wave voltammetry: SWV.