Table 2

Work condition of alternative movement wear test (oscillating tribotester).

Friction pairs used(1) 100Cr6 steel/Ti-6Al-7Nb
(2) 100Cr6 steel/Ti-6Al-4V

Sliding speed1, 15 and 25 mm s−1
Applied load (N)3, 6 and 10 N
Wear track radius5 mm
100Cr6 steel diameter10 mm
Temperature25°C
Humidity38%

We are committed to sharing findings related to COVID-19 as quickly as possible. We will be providing unlimited waivers of publication charges for accepted research articles as well as case reports and case series related to COVID-19. Review articles are excluded from this waiver policy. Sign up here as a reviewer to help fast-track new submissions.