Research Article
Synthesis of Polydopamine Functionalized Reduced Graphene Oxide-Palladium Nanocomposite for Laccase Based Biosensor
Table 1
Sensing performance comparison of different modified electrodes toward catechol
.
| Electrodes | Detection limit (µM) | Linear range (µM) | Sensitivity (µA mM−1) | Reference |
| GCE/MCN/Tyr | 0.01 | 0.05–12.5 | 593.1 | [38] | Lac/AP-rGOs/Chit/GCE | 7 | 15–700 | 15.79 | [5] | MB-MCM-41/PVA/lac | 0.331 | 4–87.98 | — | [39] | Cu-OMC/Lac/CS/Au | 0.67 | 0.67–13.8 | 104 | [40] | Lac-FSM7.0-GC | 2 | 2–100 | — | [41] | Cu/CNFs/Lac/Nafion/GCE | 1.18 | 9.5–9760 | 33.1 | [42] | N-GCE | 0.2 | 5–260 | — | [43] | Tyr-AuNPs-DHP/GCE | 0.17 | 2.5–95 | 115 | [44] | PDA-Lac-rGO-Pb/GCE | 0.03 | 0.1–263 | 18.4 | This work |
|
|
The dashes in the table represent values that were not reported in the references.
|