Abstract

The sensitivity of different renal regions to xenobiotics requires the development of a multiplex immunoassay for the simultaneous analysis of kidney biomarkers. Calbindin D28K is a distal tubule-specific protein that can be detected in urine under pathological conditions. In this study, a pair of anti-calbindin D28K antibodies was used in an immunoassay for the detection of calbindin D28K expression in rat and human kidney and urine. Comparative analysis of the immunoassay was performed on the Meso Scale Development (MSD) and Luminex platforms. Analysis on both platforms detected calbindin D28K concentrations between 100 ng/mL and 100 pg/mL. Luminex detected 10-fold the amount of calbindin D28K in samples analyzed as compared to MSD, whereas calbindin D28K level in rat and human urine was below detection limit in both platforms. The application of the immunoassays described herein may be useful in toxicological and pathological studies of distal tubular damage in rats and human.

1. Introduction

The high renal blood flow, renal biotransformation of chemicals to reactive metabolites, and the nephrons ability to concentrate tubular fluid render the kidney sensitive to xenobiotics. Due to the kidneys regional sensitivity to xenobiotics, it is important to colocalize sites of biomarkers release with pathological lesions [1].

Calbindin D28K is an intracellular, vitamin D-dependent, calcium-binding protein that is expressed in the epithelial cells of renal distal tubules [2, 3]. Previous studies have demonstrated the inhibitory effect of nephro-toxicants such as Cyclosporin A on the expression of calbindin D28K in distal tubules [4]. Furthermore, urinary analysis of patients treated with Cisplatin as well as patients treated by extracorporeal shock wave lithotripsy has indicated that the expression of calbindin D28K can be increased under pathological conditions [5, 6]. The specific localization of calbindin D28K in distal tubules along with its pathophysiological release in urine makes this protein a potential biomarker for distal tubule damage.

There is an emerging trend in pharmaceutical industry to evaluate biomarkers to determine the safety of drugs early in clinical development. These biomarkers should predict specific damage before functional loss. Limited sample volume and excess costs have led to the development of multiplex immunoassays for the simultaneous analysis of multiple biomarkers.

The aim of this study was to compare an immunoassay for calbindin D28K analysis on two multiplex platforms. The same antibody pair was used for the single-plex analysis of calbindin D28K in Luminex as compared to Meso Scale Development (MSD). Analyses were performed using rat recombinant calbindin D28K protein as a standard. Kidney homogenates were used for validating the immunoassay on both platforms. Results from this work may provide clues to the further development of a multiplex immunoassay for the simultaneous analysis of multiple kidney biomarkers.

2. Materials and Methods

2.1. Sample Preparation

Rat and human homogenates were kindly provided by AstraZeneca (UK) and Cardiff university (UK), respectively. Briefly, frozen tissue samples were chopped into small cubes (approximately  mm) and homogenized in RIPA buffer (New England Biolabs, Hitchin, UK) containing Halt protease inhibitors (Pierce, Rockford, ILL, USA) using a Polytron (Kinematica, Bohemia, NY, USA) homogenizer. Samples were homogenized for two bursts of 30 seconds and placed on ice for one minute in between bursts. Samples were then centrifuged at for 5 minutes to remove insoluble debris. Frozen urine samples from healthty rats and human individuals were used in this study.

2.2. MSD Immunoassay

Anti-mouse immunoglobulin plates (MSD, Gaithersburg, Md, USA) were used to immobilize anti-calbindin D28K monoclonal antibody from murine ascetic fluid (Sigma, Saint Louis, Mo, USA). The monoclonal antibody was diluted in Tris-Base Saline (TBS) buffer to 5  g/mL and 25  L was added per well. The plate was incubated overnight at and each well was blocked with 25  L of 5% Blocker-A (MSD) in TBS. After one hour of incubation in blocking buffer, the plate was washed three times with 0.1% Tween-containing TBS (wash-buffer). All incubations in the MSD immunoassay were done on an orbital shaker at 650 rpm. Rat recombinant calbindin D28K (Swant, Bellinzona, Switzerland) was used as a standard and a dilution series was prepared in dilution buffer, starting at 500 ng/mL. Throughout the MSD immunoassay a buffer containing 2.5% Blocker-A dissolved in TBS was used as a dilution buffer. Duplicates of both standard and samples were analyzed and 25  L were pipetted per well. After one hour of incubation, the plate was washed three times with wash-buffer and 25  L of anti-calbindin D28K polyclonal rabbit antibody (Sigma, Saint Louis, Mo, USA) was added per well. The polyclonal antibody was diluted to 2  g/mL in dilution buffer and 25  L was added per well. After one hour of incubation, plate was washed three times with wash-buffer and 25  L of sulfo-tagged goat anti-rabbit antibody (MSD), 2  g/mL, was added per well. The plate was then covered from light while incubating for 30 minutes and then washed three times with wash-buffer. Finally, 150  L of 2x MSD read buffer T was added per well and the plate was measured on the MSD Sector Imager 6000. The raw data was analyzed using the default setting of the Discovery Workbench 3.0 software (MSD).

2.3. Luminex Immunoassay

Anti-mouse IgG1 beads (Upstate, Temecula, Calif, USA) were used to capture anti-calbindin D28K murine antibody. The beads were vortexed vigorously for one minute and diluted in TBS. The plate was pre-wet with 150  L TBS for 10 minutes and then aspirated using a vacuum manifold with the bottom of the plate blotted on paper towel to remove excess fluid. Throughout the assay the beads were kept protected from light and the incubations were performed on an orbital shaker at 650 rpm. The diluted beads were vortexed for one minute and 25  L was added per well followed by 25  L of anti-calbindin D28K murine antibody diluted in TBS to a concentration of 5  g/mL. After incubating for one hour, the fluid was removed using a vacuum manifold and the wells were washed twice with 0.1% Tween-containing TBS wash-buffer. As with the MSD immunoassay, the dilution series of recombinant calbindin D28K was used as a standard. TBS containing 0.05% bovine serum antigen (BSA) was used as dilution buffer. Duplicates of both standard and samples were analyzed and 50  L were pipetted per well. After one hour of incubation, the plate was washed twice with wash-buffer and 50  L of anti-calbindin D28K polyclonal rabbit antibody, 2  g/mL, was added per well. After one hour of incubation, the plate was washed twice with wash-buffer and 50  L R-Phycoerythrin- (RPE-) conjugated goat anti-rabbit antibody (Pierce), 1.25  g/mL, was added per well. The plate was then incubated 30 minutes and washed twice with wash-buffer. Finally 150  L of sheath buffer (Bio-Rad, Hercules, Calif, USA) was added to each well and incubated for 10 minutes. The plate was measured on the Luminex100 (Luminex Corporation, Austin, Tex, USA) and analyzed using Bio-Plex Manager 3.0 (Bio-Rad). The analysis software was set to acquire data using 100  L of sample per well and to collect a total of 100 beads. The standard curve was calculated using a 5-parameter logistic fit curve generated from 7 standards.

3. Results and Discussion

The need for multiple biomarker analysis in limited sample volumes as well as the demand of decreasing costs has led to the development of multiplex immunoassay techniques. Several studies have previously compared the analysis of different biomarkers on different commercially available multiplex platforms [711]. Using the same antibody pair, in this study we compared the analysis of a distal tubule-specific protein on the MSD and Luminex platforms.

Recombinant calbindin D28K was used as a standard and was diluted to produce 8- versus 7-standard concentrations for the MSD and Luminex immunoassay, respectively. Figure 1 depicts the standard curves for both MSD and Lumniex measurement of calbindin D28K. The software used in MSD analysis regarded the lowest concentration (25 pg/mL) on standard curve to be below detection range. The signal coefficient of variation (cv) was less than 10% for both platforms, while the calculated concentration cv was high for the lower concentrations on the standard curves. MSD displayed a wider dynamic range than Luminex, detecting concentrations at a maximum of 500 ng/mL and a minimum of 50 pg/mL. The high calculated concentration cv at 50 pg/mL, set calbindin D28K lower limit of detection (lld) to 100 pg/mL on the Luminex platform.

The earliest report on a calbindin D28K immunoassay, made use of anti-calbindin D28K-coupled Sepharose beads and the standard used was native calbindin D28K purified from human kidney tissue [12]. Similar to the Luminex assay, this assay had a lld equivalent to 100 pg/mL. While the earlier-described immunoassay detected calbindin D28K in healthy individuals [5], urinary analysis of both normal rats and human indicated that the calbindin D28K level was below the detection limit in both the MSD and Luminex immunoassay (data not shown). Furthermore, it was not possible to accurately measure urinary spiked recombinant calbindin D28K, due to the recombinant protein instability in urine.

In an attempt to assess the immunoassays ability in measuring native calbindin D28K, kidney homogenates were analyzed. Since calbindin D28K is expressed in distal tubuli, rat cortical kidney homogenate was used in validating the immunoassays sensitivity and linearity. Whereas MSD had a higher sensitivity for recombinant calbindin D28K, Luminex detected calbindin D28K in kidney homogenate at the highest dilution factor tested (Table 1). To assess the immunoassays linearity, the calculated concentration (dilution concentration) was expressed as a percentage of the average of the calculated concentration from all dilutions. There was no clear difference in linearity between Luminex and MSD measurement, except at the high kidney homogenate dilutions where lower level of calbindin D28K was measured by the Luminex assay. Furthermore, Luminex detected almost 10-fold the amount of calbindin D28K as compared to MSD. Previous studies comparing different multiplex platforms have also reported quantitive differences in the analysis of different proteins [7, 8]. The difference in detected amounts of calbindin D28K could be due to technical differences between the two platforms. Immobilization of capture antibodies on beads in Luminex may provide a larger total surface than immobilization of capture antibodies at the bottom of the wells in MSD plates. This in turn may allow for higher accessibility for the capture antibody to interact with calbindin D28K in solution, and subsequently a higher detection.

To investigate the immunoassays measurement of high versus low concentrations of calbindin D28K, two different dilutions of rat cortical kidney homogenate were analyzed. Precision analysis of the two different platforms indicated that Luminex had lower cv values as compared to MSD, at both high and low concentrations of calbindin D28K (Table 2). To assess the interassay variation in both platforms, the average of the calculated calbindin D28K concentration (dilution concentration) of all the different kidney homogenate dilutions from three different experiments was compared. Despite the higher standard of deviation (SD) value, Luminex displayed a lower interassay variation as compared to MSD (Table 3).

Whereas the recombinant calbindin D28K is cloned from rat and the analyses presented so far was with rat kidney homogenate, the antibodies used in this immunoassay cross-reacts with human calbind D28K. To test the specificty of the immunoassay, homogenates from different regions of the human kidney were analyzed with MSD. The result demonstrated the immunoassays specifcity to the predominant expression of the distal tubule calbindin D28K in the cortical region (Table 4).

4. Conclusions

The methods described herein will enable future multiplex analysis of calbindin D28K in combination with other kidney-damage biomarkers, which may then be used in investigating distal tubule damage in rat and human toxicological studies. Whereas MSD had a wider dynamic range, analysis of calbindin D28K indicated that Luminex has higher sensitivity and precision. The selection of the platform most suitable for kidney biomarker analysis will depend on the other analytes available and other practical factors such as cost and ease of analysis.

Acknowledgments

This work was supported by the Technology Strategy Board in the United Kingdom.