Research Article

Development of an Open-Heart Intraoperative Risk Scoring Model for Predicting a Prolonged Intensive Care Unit Stay

Table 5

The sensitivity, specificity, positive predictive value, and negative predictive value of OHIR score at cut-off point ≥3 in this study.

OHIR scoreValue (%)95% CI

Sensitivity72.360.2–82.6
Specificity76.566.8–84.1
Positive predictive value66.754.5–77.1
Negative predictive value81.271.7–88.2
Accuracy75
Likelihood ratio 3.09
AUC for ROC of OHIR0.7460.668–0.824