Research Article
The Construct Validity and Reliability of an Assessment Tool for Competency in Cochlear Implant Surgery
Table 2
Interrater agreement for task-based checklist.
| Items | Intraclass correlation coefficient (ICC) | 95% CI | value |
| Left slightly overhanging superiorly, posteriorly, and inferiorly to help retain and control the electrode cable | 0.86 | 0.66 to 0.94 | <0.001 | Thin posterior EAC cortex maximally | 0.69 | 0.31 to 0.86 | 0.003 | Preserve a layer of bone overlying the facial nerve | 0.85 | 0.68 to 0.93 | <0.001 | Remove bone on the anterior medial surface of the fallopian canal just below the pyramidal process | 0.74 | 0.44 to 0.88 | <0.001 | Preserve a layer of bone overlying the chorda tympani | 0.84 | 0.66 to 0.93 | <0.001 | Facial recess is opened to visualize the round window niche | 0.93 | 0.84 to 0.97 | <0.001 | Cochleostomy is drilled through the promontory just anterior and inferior to the round window membrane | 0.79 | 0.53 to 0.91 | 0.037 | The bony promontory overlying the round window niche has been removed | — | | — |
| All variables | 0.92 | 0.86 to 0.96 | <0.001 |
|
|