Erratum

Erratum to “Detergent-Enzymatic Decellularization of Swine Blood Vessels: Insight on Mechanical Properties for Vascular Tissue Engineering”

Table 1

Median and quartile values of mechanical parameters for native, defrozen, and decellularized arterial vessels.

Mechanical parametersNativeDefrozenDecellularized
Median25–75 percentilesMedian25–75 percentilesMedian25–75 percentiles

Young’s modulus [MPa]0.18670.1396–0.20160.19650.1473–0.24860.21520.1699–0.2365
Compliance [1/mmHg]0.0026060.002330–0.0040330.0026440.001671–0.0035740.0022700.001869–0.003454
Ultimate stress [MPa]1.5541.309–1.7971.8891.658–2.2802.0071.540–2.324
Ultimate strain [mm/mm]1.8301.499–2.1341.8301.274–1.6211.3471.174–1.402
Stress relaxation [%]57.7154.71–59.2375.1258.31–86.8877.9771.14–82.79
Burst pressure [mmHg]23311886–265727352256–302725602166–2939
Suture retention [g]881.9545.2–953.8705.4375.8–1055731.7490.4–767.3