The Fetal Modified Myocardial Performance Index: Is Automation the Future?

Table 1

Technique and machine settings used in various studies (adapted from Mahajan et al., in press [46]).

Angle of insonation (°)WMF (Hz)Sample volume (mm)Sweep velocity (cm/s)Doppler gainPlacement of time cursor

Tei, 1995 [8]NDNDND10NDBeginning of mitral inflow and aortic outflow waveforms.
Hernandez-Andrade et al., 2005 [5]<3070315Min.Beginning of valve clicks.
Van Mieghem et al., 2009 [49]<15≥120ND10NDEnd of closing clicks to beginning of opening clicks.
Meriki et al., 2012 [48]<15300315Min.Peak of valve clicks.
Lobmaier et al., 2014 for Siemens Antares machine* [56]<1528141560 dBBeginning of valve clicks.
Lobmaier et al., 2014 for Voluson 730 Expert machine* [56]<15210415−10 dBBeginning of valve clicks.

WMF: wall motion filter; ND: not defined; min.: minimum.
*Values displayed are the “optimal settings” for each ultrasound machine trialled in this study, as various settings were compared.