Research Article

Source-Space Cross-Frequency Amplitude-Amplitude Coupling in Tinnitus

Table 1

Participant characteristics. SD: standard deviation. Note that audiogram data are missing for two control subjects.

TinnitusNo tinnitus

GenderMale1410χ2(1) = 0.031
Female149 = 0.90

AgeMean
(SD)
54.7
(12.8)
39.0
(14.0)
(45) = 3.96

Pure-tone average (0.25–8 kHz) Mean left
(SD)
25.2
(18.5)
4.5
(6.4)
(43) = 4.43
Mean right
(SD)
21.1
(16.5)
4.0
(5.7)
(43) = 4.11

Tinnitus Handicap Inventory (THI)Mean (score)
(SD)
39.9
(21.1)
NA

Hyperacusis3NA
Mean (score)
(SD)
17.0
(9.4)
NA

TI qualityTonal19NA
Hissing3NA
Ringing6NA

TI lateralityRight6NA
Left11NA
Bilateral11NA

TI duration (years)Mean
(SD)
12.9
(15.1)
NA