Clinical Study

A Novel Operative Procedure for Pelvic Organ Prolapse Utilizing a MRI-Visible Mesh Implant: Safety and Outcome of Modified Laparoscopic Bilateral Sacropexy

Table 2

Pre- and postoperative quantification of the prolapse.

POP-Q measurements (cm)
AaBaCDApBp

Preoperative
 Mean1.22.1−0.2−1.5−2.1−2.1
 Median1.01.5−0.5−2.0−2.5−2.5
 Range0 to +30 to +5−4 to +3−4 to +1−3 to +1−3 to +1
10 10 10 7*10 10
Postoperative
 Mean−1.5−1.1−6.3−8.0−2.7−2.7
 Median−1.0−1.0−6.0−8.0−3.0−3.0
 Range−3 to 0−3 to 0−7 to −5−7 to −9−3 to −1−3 to −1
10 10 10 7*10 10
Diff. postoperative to preoperative
 Mean2.73.26.16.50.60.6
 Median22.55.560.50.5
 Range1 to 41 to 63 to 104 to 100 to 30–3
10 10 10 7*10 10

3 patients had a hysterectomy in their past medical history, so that measurement D is not applicable.