Research Article

A Modified Carbon Monoxide Breath Test for Measuring Erythrocyte Lifespan in Small Animals

Table 2

Comparison of RBC lifespan determined by biotin labeling versus CO breath test methods.

GroupRBC lifespan (d)p
Biotin labelingCO breath test

CON551 ± 2.749 ± 5.90.515
RIB10533 ± 1.331 ± 4.00.200
RIB20527 ± 0.825 ± 2.90.108

versus CON. versus RIB10.