Research Article

Mechanical and Metallurgical Properties of Various Nickel-Titanium Rotary Instruments

Figure 3

Results from the cyclic fatigue fracture test. (a) The mean number of cycles to fracture (NCF) as determined by the cyclic fatigue fracture test, in ascending order. Groups under the same bar did not show significant difference (). (b) The mean NCF as determined by the cyclic fatigue fracture test at continuous rotation and reciprocating rotation. An indicates a significant difference (). PF: ProFile, OS: One Shape, PN: ProTaper NEXT, RC: Reciproc, WO: WaveOne, and HF: HyFlex CM.
(a)
(b)