Research Article

Standardized Duplex Ultrasound-Based Protocol for Early Diagnosis of Transplant Renal Artery Stenosis: Results of a Single-Institution Retrospective Cohort Study

Table 4

Comparison of SPV, RI, SBP, DBP, and eGFR values among the TRAS-patients before and after stenting placement. TRAS = transplant renal artery stenosis; SPV = systolic peak velocity; RI = resistive indexes.

Prestenting ()Poststenting () value

Systolic peak velocity (SPV) at the level of TRAS (m/sec)  
(median, IQR)
3,0 (2,6–3,6)1,4 (1,2–1,7)<0,001

Resistive index (RI) at parenchymal level (n)  
(median, IQR)
0,68 (0,62–0,73)0,72 (0,69–0,77)0,01

Systolic blood pressure (mmHg)  
(median, IQR)
145 (140–160)140 (120–150)0,1

Diastolic blood pressure (mmHg)  
(median, IQR)
85 (80–90)80 (75–85)0,06

eGFR (ml/min/m2)  
(median, IQR)
49 (35–56)53 (41–63)0,11