Research Article
The Augment of the Stability in Locking Compression Plate with Intramedullary Fibular Allograft for Proximal Humerus Fractures in Elderly People
Table 2
Functional outcomes and complications of patients in two groups.
| Variable | Group I (n=42) | Group II (n=47) | P-value |
| >5mm loss of reduction | 9 | 2 | 0.022 | Functional outcomes | DASH | 49.00 | 36.17 | 0.001 | CMS | 70.29 | 74.38 | 0.020 | Complications | Varus malunion | 8 | 2 | 0.042 | Screw perforation | 6 | 1 | 0.049 | Avascular necrosis | 3 | 5 | 0.717 | Total complications | 17 | 8 | 0.018 |
|
|