Research Article

Effect of Transmural Differences in Excitation-Contraction Delay and Contraction Velocity on Left Ventricle Isovolumic Contraction: A Simulation Study

Table 1

Values of and of IVC duration obtained from the model simulations under specified conditions.

IVC 

Control178060
Constant EMD174071
Constant MSV111094
Constant EMD and MSV1100104