Journals
Publish with us
Publishing partnerships
About us
Blog
BioMed Research International
Journal overview
For authors
For reviewers
For editors
Table of Contents
Special Issues
BioMed Research International
/
2018
/
Article
/
Tab 2
/
Research Article
Kirschner Wire Temporary Intramedullary Fixation Combined with a Locking Anatomical Plate versus a Reconstruction Plate in the Treatment of Comminuted Clavicular Fractures: A Retrospective Study
Table 2
Operative details of all patients.
(n=52)
(
n
=60)
T
value,
P-value
Operation time (min)
45.0±7.5
62.0±15.5
-7.20, 0.000
Intraoperative blood loss (ml)
25.0±16.5
63.0±19.7
-10.96, 0.000
Total incision length (cm)
6.4±0.8
10.3±1.7
-15.14, 0.000
pain score 24h after surgery (points)
1.9±0.5
4.4±0.4
-29.37, 0.000
Fracture healing time (weeks)
9.3±1.2
11.4±1.3
-8.834, 0.000
Incidence of complication
0
8.3% (5/60)
p
=0.0
Neer score3 months after surgery
97.8±1.4
98.1±1.2
-1.22, 0.225
’s test.