Table of Contents Author Guidelines Submit a Manuscript
BioMed Research International
Volume 2018, Article ID 5049605, 6 pages
https://doi.org/10.1155/2018/5049605
Research Article

Influence of Manufacturing Methods of Implant-Supported Crowns on External and Internal Marginal Fit: A Micro-CT Analysis

1School of Dentistry, University of Ribeirão Preto, Ribeirão Preto, SP, Brazil
2Department of Dental Materials and Prosthodontics, School of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto, SP, Brazil

Correspondence should be addressed to Erica A. Gomes; rb.moc.oohay@semogaacire

Received 2 August 2017; Accepted 21 November 2017; Published 23 January 2018

Academic Editor: Nick Silikas

Copyright © 2018 Izabela C. M. Moris et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Linked References

  1. N. R. F. A. Silva, E. A. Bonfante, R. A. Zavanelli, V. P. Thompson, J. L. Ferencz, and P. G. Coelho, “Reliability of metalloceramic and zirconia-based ceramic crowns,” Journal of Dental Research, vol. 89, no. 10, pp. 1051–1056, 2010. View at Publisher · View at Google Scholar · View at Scopus
  2. G. Pompa, S. Di Carlo, F. De Angelis, M. P. Cristalli, and S. Annibali, “Comparison of conventional methods and laser-assisted rapid prototyping for manufacturing fixed dental prostheses: an in vitro study,” BioMed Research International, vol. 2015, Article ID 318097, 2015. View at Publisher · View at Google Scholar · View at Scopus
  3. P. Gómez-Cogolludo, R. Castillo-Oyagüe, C. D. Lynch, and M.-J. Suárez-García, “Effect of electric arc, gas oxygen torch and induction melting techniques on the marginal accuracy of cast base-metal and noble metal-ceramic crowns,” Journal of Dentistry, vol. 41, no. 9, pp. 826–831, 2013. View at Publisher · View at Google Scholar · View at Scopus
  4. U. Işeri, Z. Özkurt, and E. Kazazoǧlu, “Shear bond strengths of veneering porcelain to cast, machined and lasersintered titanium,” Dental Materials, vol. 30, no. 3, pp. 274–280, 2011. View at Publisher · View at Google Scholar · View at Scopus
  5. R. P. O'Connor, J. R. Mackert Jr., M. L. Myers, and E. E. Parry, “Castability, opaque masking, and porcelain bonding of 17 porcelain-fused-to-metal alloys,” Journal of Prosthetic Dentistry, vol. 75, no. 4, pp. 367–374, 1996. View at Publisher · View at Google Scholar · View at Scopus
  6. Y. Ucar, T. Akova, M. S. Akyil, and W. A. Brantley, “Internal fit evaluation of crowns prepared using a new dental crown fabrication technique: laser-sintered Co-Cr crowns,” Journal of Prosthetic Dentistry, vol. 102, no. 4, pp. 253–259, 2009. View at Publisher · View at Google Scholar · View at Scopus
  7. A. Örtorp, D. Jönsson, A. Mouhsen, and P. Vult von Steyern, “The fit of cobalt-chromium three-unit fixed dental prostheses fabricated with four different techniques: a comparative in vitro study,” Dental Materials, vol. 27, no. 4, pp. 356–363, 2011. View at Publisher · View at Google Scholar · View at Scopus
  8. L. Steinebrunner, S. Wolfart, K. Ludwig, and M. Kern, “Implant-abutment interface design affects fatigue and fracture strength of implants,” Clinical Oral Implants Research, vol. 19, no. 12, pp. 1276–1284, 2008. View at Publisher · View at Google Scholar · View at Scopus
  9. J. R. de Oliveira Bauer, R. H. M. Grande, L. E. Rodrigues-Filho, M. M. Pinto, and A. D. Loguercio, “Does the casting mode influence microstructure, fracture and properties of different metal ceramic alloys?” Brazilian Oral Research, vol. 26, no. 3, pp. 190–196, 2012. View at Publisher · View at Google Scholar · View at Scopus
  10. K. Kikuchi, N. Akiba, A. Sadr, Y. Sumi, J. Tagami, and S. Minakuchi, “Evaluation of the marginal fit at implant-abutment interface by optical coherence tomography,” Journal of Biomedical Optics, vol. 19, no. 5, Article ID 055002, 2014. View at Publisher · View at Google Scholar · View at Scopus
  11. D. Xia, H. Lin, S. Yuan, W. Bai, and G. Zheng, “Dynamic fatigue performance of implant-abutment assemblies with different tightening torque values,” Bio-medical Materials Engeneering, vol. 24, no. 6, pp. 2143–2149, 2014. View at Google Scholar
  12. E. A. Bonfante, M. Suzuki, F. C. Lorenzoni et al., “Probability of survival of implant-supported metal ceramic and CAD/CAM resin nanoceramic crowns,” Dental Materials, vol. 31, no. 8, pp. e168–e177, 2015. View at Publisher · View at Google Scholar · View at Scopus
  13. I. C. M. Moris, A. C. L. Faria, R. F. Ribeiro, and R. C. S. Rodrigues, “Abutments with reduced diameter for both cement and screw retentions: analysis of failure modes and misfit of abutment–crown–connections after cyclic loading,” Clinical Oral Implants Research, vol. 28, no. 4, pp. 432–436, 2017. View at Publisher · View at Google Scholar · View at Scopus
  14. H. Wang, Q. Feng, N. Li, and S. Xu, “Evaluation of metal-ceramic bond characteristics of three dental Co-Cr alloys prepared with different fabrication techniques,” Journal of Prosthetic Dentistry, vol. 116, no. 6, pp. 916–923, 2016. View at Publisher · View at Google Scholar · View at Scopus
  15. S. C. Kano, P. P. Binon, and D. A. Curtis, “A classification system to measure the implant-abutment microgap,” The International Journal of Oral & Maxillofacial Implants, vol. 22, no. 6, pp. 879–885, 2007. View at Google Scholar · View at Scopus
  16. W. C. Chen, F. Y. Teng, and C. C. Hung, “Characterization of Ni—Cr alloys using different casting techniques and molds,” Materials Science & Engineering C, Materials for Biological Applications, vol. 1, no. 35, pp. 231–238, 2014. View at Google Scholar
  17. I. C. M. Moris, A. C. L. Faria, M. D. G. C. de Mattos, R. F. Ribeiro, and R. C. S. Rodrigues, “Mechanical analysis of conventional and small diameter conical implant abutments,” The Journal of Advanced Prosthodontics, vol. 4, no. 3, pp. 158–161, 2012. View at Publisher · View at Google Scholar · View at Scopus
  18. J. R. P. Jorge, V. A. R. Barão, J. A. Delben, and W. G. Assunção, “The role of implant/abutment system on torque maintenance of retention screws and vertical misfit of implant-supported crowns before and after mechanical cycling,” The International Journal of Oral & Maxillofacial Implants, vol. 28, no. 2, pp. 415–422, 2013. View at Publisher · View at Google Scholar · View at Scopus
  19. Z. Huang, L. Zhang, J. Zhu, and X. Zhang, “Clinical marginal and internal fit of metal ceramic crowns fabricated with a selective laser melting technology,” Journal of Prosthetic Dentistry, vol. 113, no. 6, pp. 623–627, 2015. View at Publisher · View at Google Scholar · View at Scopus
  20. H.-S. Pak, J.-S. Han, J.-B. Lee, S.-H. Kim, and J.-H. Yang, “Influence of porcelain veneering on the marginal fit of digident and lava CAD/CAM zirconia ceramic crowns,” The Journal of Advanced Prosthodontics, vol. 2, no. 2, pp. 33–38, 2010. View at Publisher · View at Google Scholar · View at Scopus
  21. S. Gunsoy and M. Ulusoy, “Evaluation of marginal/internal fit of chrome-cobalt crowns: direct laser metal sintering versus computer-aided design and computer-aided manufacturing,” Nigerian Journal of Clinical Practice, vol. 19, no. 5, pp. 636–644, 2016. View at Publisher · View at Google Scholar · View at Scopus
  22. M.-E. Krasanaki, S. Pelekanos, M. Andreiotelli, S.-O. Koutayas, and G. Eliades, “X-ray microtomographic evaluation of the influence of two preparation types on marginal fit of CAD/CAM alumina copings: a pilot study,” International Journal of Prosthodontics, vol. 25, no. 2, pp. 170–172, 2012. View at Google Scholar · View at Scopus
  23. S. Pelekanos, M. Koumanou, S.-O. Koutayas, S. Zinelis, and G. Eliades, “Micro-CT evaluation of the marginal fit of different In-Ceram alumina copings,” The European Journal of Esthetic Dentistry, vol. 4, no. 3, pp. 278–292, 2009. View at Google Scholar · View at Scopus
  24. M. Borba, P. F. Cesar, J. A. Griggs, and Á. D. Bona, “Adaptation of all-ceramic fixed partial dentures,” Dental Materials, vol. 27, no. 11, pp. 1119–1126, 2011. View at Publisher · View at Google Scholar · View at Scopus
  25. W. G. Assunção, V. A. R. Barão, J. A. Delben, É. A. Gomes, and I. R. Garcia, “Effect of unilateral misfit on preload of retention screws of implant-supported prostheses submitted to mechanical cycling,” Journal of Prosthodontic Research, vol. 55, no. 1, pp. 12–18, 2011. View at Publisher · View at Google Scholar · View at Scopus
  26. P.-I. Branemark, “Osseointegration and its experimental background,” The Journal of Prosthetic Dentistry, vol. 50, no. 3, pp. 399–410, 1983. View at Publisher · View at Google Scholar · View at Scopus
  27. S. C. Kano, G. Bonfante, R. Hussne, and A. F. Siqueira, “Use of base metal casting alloys for implant framework: marginal accuracy analysis,” Journal of Applied Oral Science, vol. 12, no. 4, pp. 337–343, 2004. View at Publisher · View at Google Scholar
  28. V. Harish, S. A. Mohamed Ali, N. Jagadesan et al., “Evaluation of internal and marginal fit of two metal ceramic system – In vitro study,” Journal of Clinical and Diagnostic Research, vol. 8, no. 12, pp. ZC53–ZC56, 2014. View at Publisher · View at Google Scholar · View at Scopus
  29. G. Davidowitz and P. G. Kotick, “The use of CAD/CAM in dentistry,” Dental Clinics of North America, vol. 55, no. 3, pp. 559–570, 2011. View at Publisher · View at Google Scholar · View at Scopus
  30. W. W. Cheng, C. P. Ju, and J. H. Chern Lin, “Structure, castability and mechanical properties of commercially pure and alloyed titanium cast in graphite mould,” Journal of Oral Rehabilitation, vol. 34, no. 7, pp. 528–540, 2007. View at Publisher · View at Google Scholar · View at Scopus