Research Article

A High Throughput HPLC-MS/MS Method for Antihypertensive Drugs Determination in Plasma and Its Application on Pharmacokinetic Interaction Study with Shuxuetong Injection in Rats

Table 3

Precision and accuracy of the analytes in rat plasma (n = 6).

CompoundsSpiked  
concentration (ng/mL)
IntradayInterday
Measured (ng/mL)RE  
(%)
RSD (%)Measured (ng/mL)RE (%)RSD (%)

metoprolol tartrate2021.16 ± 0.915.84.321.16 ± 0.645.83.0
400431.98 ± 10.658.02.5427.53 ± 12.126.92.8
40003725.53 ± 113.06-6.93.03784.38 ± 153.35-5.44.1
hydrochlorothiazide2524.07 ± 1.70-3.77.126.07 ± 2.374.39.1
500531.80 ± 28.556.45.4524.21 ± 29.444.85.6
50004551.15 ± 42.31-9.00.94510.25 ± 147.90-9.83.3
55.27 ± 0.335.56.25.34 ± 0.306.95.6
nifedipine100100.64 ± 2.470.62.5106.67 ± 5.206.74.9
1000909.20 ± 13.18-9.11.5902.93 ± 43.30-9.74.8
5056.37 ± 3.1212.75.555.30 ± 1.9410.63.5
valsartan10001074.78 ± 24.167.52.31083.06 ± 23.848.32.2
100008647.62 ± 294.77-13.53.48813.82 ± 376.14-11.94.3