Journals
Publish with us
Publishing partnerships
About us
Blog
BioMed Research International
Journal overview
For authors
For reviewers
For editors
Table of Contents
Special Issues
BioMed Research International
/
2020
/
Article
/
Tab 1
/
Research Article
Biomechanical Comparison of a New Memory Compression Alloy Plate versus Traditional Titanium Plate for Anterior Cervical Discectomy and Fusion: A Finite Element Analysis
Table 1
Material properties assigned to the intact FE model.
Component element
Type
Young modulus (MPa)
Poisson ratio
Cross-sectional area (mm
2
)
Cortical bone
C3D4
12000
0.3
/
Cancellous bone
C3D4
450
0.2
/
Endplate
C3D4
500
0.4
/
Articular cartilage
C3D4
10.4
0.4
/
Nucleus pulpous
C3D8H
1
0.49
/
Annulus fibers
T3D2
110
0.3
/
Annulus ground substance
C3D8H
3.4
0.4
/
Anterior longitudinal ligament
T3D2
10
0.3
6
Posterior longitudinal ligament
T3D2
10
0.3
5
Ligamentum flavum ligament
T3D2
1.5
0.3
5
Interspinous ligament ligament
T3D2
1.5
0.3
10
Supraspinous ligament
T3D2
1.5
0.3
5
Ligamenta intertransversaria
T3D2
1.5
0.3
5
Capsular
T3D2
10
0.3
46