Research Article

Comparison of Primer-Probe Sets among Different Master Mixes for Laboratory Screening of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2)

Table 1

Volumes of reagents for reactions using two different polymerase enzymes combined with three primer-probe sets.

No.ReagentLightCycler Multiplex RNA Virus Master (TIB-Molbiol)LightCycler Multiplex RNA Virus Master (IDT/Phu Sa)Invitrogen™ SuperScript™ III One-Step RT-PCR System (TIB-Molbiol)Invitrogen™ SuperScript™ III One-Step RT-PCR System (IDT/Phu Sa)

1H2O (RNAse free)10.4 μL8.4 μL5.6 μL3.6 μL
2Reaction mix4.0 μL4.0 μL12.5 μL12.5 μL
3Primer E_Sarbeco_F10.5 μL1.0 μL0.5 μL1.0 μL
4Primer E_Sarbeco_R21.0 μL1.0 μL
5Primer E_Sarbeco_R20.5 μL0.5 μL
6MgSO4 (50 nM)0.4 μL-0.4 μL0.4 μL
7RT enzyme0.1 μL0.1 μL1.0 μL1.0 μL
8Template RNA5.0 μL5.0 μL5.0 μL5.0 μL
Total20 μL20 μL25 μL25 μL