Research Article

Radial Undersampling-Based Interpolation Scheme for Multislice CSMRI Reconstruction Techniques

Table 1

Comparison of the proposed radial undersampling schemes with 1D- and 2D-VRDU schemes, along with CS. The assessment has been done on 3 consecutive slices and averaged (slices 165-167 of the knee dataset).

Assessment parameter1D-VRDU
CS-9%
1D-VRDU
iCS-9%
2D-VRDU
CS-5%
2D-VRDU
FiCS-5%
UA radial
CS-5%
UA radial
FiCS-5%
GA radial
CS-5%
GA radial
FiCS-5%

SSIM0.55960.72260.78340.80080.79950.83880.76690.8339
FSIM0.93870.97330.97130.94630.92010.95930.91500.9516
MSE0.03980.00580.00560.00230.00080.00040.00100.0005
PSNR14.00223.77922.63626.36730.73833.22129.79732.778
CORR0.93170.95220.97620.96470.94760.97030.93580.9671
SI48.88501.64374.46275.61175.06267.6346.07276.44
PIQE65.79130.91562.12173.85072.57754.58279.57465.978