Research Article

Fault Diagnosis for Analog Circuits by Using EEMD, Relative Entropy, and ELM

Table 1

Fault configuration for Sallen-Key filter circuit.

Fault IDFaultsNominal valuesFaulty parameter ranges

F0No-fault
F1R1 5.18k[0.5, 4.92k]
F2R1 5.18k[5.44k, 51meg]
F3R2 1k[0.1, 0.95k]
F4R2 1k[1.05k, 10meg]
F5R3 2k[0.2, 1.9k]
F6R3 2k[2.1k, 20meg]
F7R4 4k[0.4, 3.8k]
F8R4 4k [4.2k, 40meg]
F9R5 4k[0.4, 3.8k]
F10R5 4k[4.2k, 40meg]
F11C1 5n[0.5p, 4.75n]
F12C1 5n[5.25n, 50u]
F13C2 5n[0.5p, 4.75n]
F14C2 5n[5.25n, 50u]