Research Article

Decoding Motor Imagery through Common Spatial Pattern Filters at the EEG Source Space

Table 2

10 × 10-fold cross-validation performance in terms of mean Cohen’s kappa value, of the developed method in source and sensor level, and the method developed by the winner of BCI Competition IV, dataset 2a.

SubjectA01TA02TA03TA04TA05TA06TA07TA08TA09TMean

Sensor0.480.270.570.190.170.170.420.560.640.39
Source0.500.340.610.300.300.260.560.630.660.46
Winner FBCSP0.760.470.830.480.600.340.860.800.780.65