Canadian Journal of Gastroenterology and Hepatology

Canadian Journal of Gastroenterology and Hepatology / 2013 / Article

Original Article | Open Access

Volume 27 |Article ID 276043 | https://doi.org/10.1155/2013/276043

Aydin Şeref Köksal, İsmail Hakkı Kalkan, Serkan Torun, İsmail Taşkıran, Erkin Öztaş, Ertuğrul Kayaçetin, Nurgül Şaşmaz, "A Simple Method to Improve Adenoma Detection Rate During Colonoscopy: Altering Patient Position", Canadian Journal of Gastroenterology and Hepatology, vol. 27, Article ID 276043, 4 pages, 2013. https://doi.org/10.1155/2013/276043

A Simple Method to Improve Adenoma Detection Rate During Colonoscopy: Altering Patient Position

Received31 Mar 2013
Accepted12 May 2013

Abstract

BACKGROUND: Colonoscopy is currently considered to be the gold standard method for detecting and removing adenomatous polyps. However, tandem colonoscopy studies reveal a pooled polyp miss rate of 22%.OBJECTIVE: A prospective randomized trial was conducted to assess whether alteration of patient position during colonoscopy withdrawal increases the adenoma detection rate (ADR).METHOD: The study group included 120 patients who presented for elective colonoscopic examination. After reaching the cecum, patients were randomly assigned in a 1:1 ratio to examination in either the left lateral position or other positions (left lateral position for the cecum, ascending colon and hepatic flexure; supine for transverse colon; and supine and right lateral position for splenic flexure, descending and sigmoid colon) first. Examination of the colon was performed segment by segment. The size, morphology and location of all polyps were recorded. Polyps were removed immediately after examination of a colon segment when all positions were completed. ADR and polyp detection rates (PDR) were calculated.RESULTS: A total of 102 patients completed the study. Examination in the left lateral position revealed 66 polyps in 31 patients (PDR 30.3%) and 42 adenomas in 24 patients (ADR 23.5%). PDR increased to 43.1% (81 polyps in 44 patients) and the ADR to 33.3% (53 adenomas in 34 patients) after the colon was examined in the additional positions (P<0.001 and P=0.002, respectively). The increase in the number of adenomas detected was statistically significant in the transverse and sigmoid colon. The addition of position changes led to a 9.8% increase in the ADR in the transverse colon, splenic flexure, and descending and sigmoid colon. The frequency of surveillance interval was shortened in nine (8.8%) patients after examination of the colon in dynamic positions.CONCLUSION: Alteration of patient position during colonoscopy withdrawal is a simple and effective method to improve ADR.

Copyright © 2013 Hindawi Publishing Corporation. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.


More related articles

 PDF Download Citation Citation
 Order printed copiesOrder
Views254
Downloads335
Citations

Related articles

We are committed to sharing findings related to COVID-19 as quickly as possible. We will be providing unlimited waivers of publication charges for accepted research articles as well as case reports and case series related to COVID-19. Review articles are excluded from this waiver policy. Sign up here as a reviewer to help fast-track new submissions.