Research Article
Optimisation of a Generic Ionic Model of Cardiac Myocyte Electrical Activity
Table 1
Parameter values for single AP dataset-based optimisation.
| Parameter | Description | cSAN | pSAN | RA |
| | Maximum conductance (S/cm2) | 95.71 | 60.29 | 33.55 | | Reversal potential of (mV) | −91.74 | −92.80 | −97.71 | | Maximum value of | 4932.74 | 4990.73 | 3099.16 | | Slope value for | −1.84 | −2.92 | −0.10 | | Maximum value of | 15.26 | 41.15 | 4477.72 | | Slope value for | 2.48 | 5.00 | 0.15 | | value for and | −30.44 | −62.41 | −77.65 | | Maximum value of | 1.40 | 6.61 | 170.9 | | Slope value for | −3.86 | −2.09 | −0.01 | | Maximum value of | 7.92 | 7.81 | 0.01 | | Slope value for () | 0.10 | 0.92 | 0.19 | | value for and | −36.17 | −53.46 | −80.46 |
| | Maximum conductance (µS/cm2) | 17722.1 | 17966.7 | 9962.91 | | Reversal potential of (mV) | 11.38 | 6.98 | 14.54 | | Maximum value of | 0.44 | 2.80 | 300.89 | | Slope value for | −4.98 | −4.99 | −0.20 | | Maximum value of | 3851.95 | 4612.17 | 4030.31 | | Slope value for | 0.26 | 0.70 | 0.02 | | value for and | −47.98 | −70.14 | −51.73 | | Maximum value of | 4.36 | 9.95 | 16.86 | | Slope value for | 3.51 | 3.04 | 0.20 | | Maximum value of | 43.47 | 62.65 | 52.61 | | Slope value for | −4.47 | −4.67 | −0.18 | | value for and | −36.24 | −69.46 | −75.74 |
| | Maximum conductance (S/cm2) | 3.70 | 4.00 | 1.74 | | Reversal potential of | −42.59 | −69.32 | −58.98 |
|
|