3D Alternating Direction TV-Based Cone-Beam CT Reconstruction with Efficient GPU Implementation
Table 4
RMSEs for two reconstruction algorithms.
ā
20
40
60
80
100
ASD-POCS
0.1301
0.0150
0.0082
0.0058
0.0037
New method
0.1000
0.0102
0.0055
0.0045
0.0028